    The 3 GCK Low-Voltage guide Withdrawable Switchgear is a modular, metal-enclosed, withdrawable type low-voltage panel designed for high-reliability power distribution, motor control, and reactive power compensation. It is suitable for applications requiring high levels of automation and remote communication such as large power stations, petrochemical systems, and intelligent power grids.

    Compliant with IEC 60439-1, the GCK Withdrawable Switchgear ensures excellent safety, maintainability, and configuration flexibility, with an enclosure protection degree of IP30 or IP40.

    GCK Low Voltage Withdrawable Switchgear for Motor Control and Distribution

    Technical Specifications of GCK Low Voltage Switchgear

    ParameterSpecification
    Rated Insulation Voltage690V / 1000V
    Rated Operating Voltage400V / 690V
    Rated Frequency50Hz / 60Hz
    Impulse Withstand Voltage8kV
    Auxiliary Circuit VoltageAC380/220V, DC110/220V
    Over-voltage CategoryClass III
    Rated Current (Main Bus)Up to 5000A
    Rated Current (Vertical Bus)Up to 1000A
    Protection LevelIP30 / IP40
    Busbar Configuration3P4W / 3P5W
    Standard ComplianceIEC60439-1
    Structure TypeModular, Drawer-type, Compartmentalized

    Application Fields

    • Thermal and hydropower stations
    • Chemical & petrochemical plants
    • Large industrial automation systems
    • Commercial and municipal buildings
    • Renewable energy power control panels

    Cabinet Structure and Features

    Cabinet Framework

    • Modular C-type frame using FA28 or KB type steel.
    • All structural components are corrosion-resistant and galvanized.
    • Top covers are removable for easy busbar installation.
    • Surface treated with epoxy powder electrostatic coating.

    Withdrawable Functional Units

    • Units available in 1/2U, 1U, 2U, 3U heights (200mm–600mm).
    • Interlocked drawer mechanism with clear test/isolation/working position indicators.
    • Optional padlock support for secure maintenance.
    • Each MCC panel can install up to 18 drawers of 1/2 unit size.

    Safety & Isolation

    • Compartment doors interlocked with switch positions.
    • Drawer equipped with main circuit plug, auxiliary plug, grounding plug.
    • Vertical busbar shielding ensures safety during drawer movement.
    • Five-proof interlock design supports safe live maintenance.

    Cabinet Dimensions (in mm)

    Cabinet TypeWidth (A)Internal Width (B)
    Feeder Cabinet600, 800486
    Power/Bus Cabinet800, 1000686, 886
    Motor Control Cabinet600, 800
    Power Compensation Panel600, 800, 1000
    Depth (all types)800 / 1000 (recommended)

    Busbar Specifications

    Rated Current (A)Copper Bus Size (mm)
    63050 × 5
    125060 × 10
    160080 × 10
    2000100 × 10
    25002 × (80 × 10)
    31502 × (100 × 10)

    Operating Conditions

    Environmental FactorSpecification
    Ambient Temperature-5℃ ~ +40℃
    Storage Temperature-25℃ ~ +55℃ (Max short-term: 70℃)
    Relative Humidity≤50% at +40℃; up to 90% at +20℃
    Altitude≤2000m
    Installation Inclination≤5°
    Corrosive/Flammable GasesNot allowed

    Frequently Asked Questions

    Q1: What is the advantage of GCK withdrawable design?
    A: It allows safe, quick maintenance and replacement without powering down the entire switchgear panel.

    Q2: Can the GCK be customized for special busbar guide configurations?
    A: Yes. Horizontal or vertical busbars can be arranged at the top or bottom per project needs.

    Q3: Is GCK compliant with international safety standards?
    A: Yes. It complies with IEC60439-1 and supports protection classes IP30/IP40.